Occupational Hearing Loss in Dentistry

Occupational hearing loss can result from exposure to hazardous noise or ototoxic chemicals.1Centers for Disease Control and Prevention. The National Institute for Occupational Safety and Health (NIOSH). Occupational hearing loss (OHL) surveillance. Available at: https://www.cdc.gov/niosh/topics/ohl/default.html. In the United States, an estimated 22 million individuals are occupationally exposed to hazardous noise and an estimated 3% of workers overall have noise-induced occupational hearing loss (NOHL).2Masterson EA, Bushnell PT, Themann CL, Morata TC. Hearing impairment among noise-exposed workers — United States, 2003–2012. MMWR 2016;65(15):389-94 The dental team is exposed to occupational noise on a daily basis in the course of performing procedures. Concern over the possibility of NOHL among dentists was reported in 1960.3Cantwell KR, Tunturi AR, Manny VR. Noise from high-speed hand-pieces. J Am Dent Assoc 1960;61:571-7. Since then, numerous studies have assessed noise levels and investigated NOHL in the dental setting. Understanding the potential risk for NOHL is important and undertaking mitigation efforts can prevent this condition.

Measuring Noise Levels

Noise levels are typically defined using an A-weighted decibel scale (dbA).4Occupational Safety and Health Administration. How loud is too loud? Occupational noise exposure. Available at: https://www.osha.gov/SLTC/noisehearingconservation/ This scale is designed to closely match how we perceive loudness, by giving less weight to low and high frequencies. Since the scale is logarithmic, a small change in dbA represents a large change in loudness.4Occupational Safety and Health Administration. How loud is too loud? Occupational noise exposure. Available at: https://www.osha.gov/SLTC/noisehearingconservation/,5Measurement in decibels: What is the difference between dB and dB(A)? General Acoustics, May 14, 2019. Available at: https://www.softdb.com/difference-between-db-dba/. Hazardous noise is typically defined as a time-weighted average of ≥85 dbA for an 8-hour workday.4Occupational Safety and Health Administration. How loud is too loud? Occupational noise exposure. Available at: https://www.osha.gov/SLTC/noisehearingconservation/ However, the Occupational Safety and Health Administration (OSHA) has a permissible exposure limit of 90 dbA for an 8-hour workday while, based on updated information, the National Institute for Occupational Safety and Health (NIOSH) recommends <85 dbA.4Occupational Safety and Health Administration. How loud is too loud? Occupational noise exposure. Available at: https://www.osha.gov/SLTC/noisehearingconservation/ In addition, OSHA allows 4 hours at 95 dbA and 2 hours at 100 dbA daily (halving the time for each 5 dbA increase), while at 100 dBA NIOSH recommends <15 minutes per day (and uses a 3 dbA increase for halving recommended exposure times). While some studies report db (or dbA) SPL rather than dbA, the measured number is considered synonymous at ≥1000 Hz, diverging at lower frequencies.6Chasin M. For whom the decibel tolls: The dBA vs dB SPL war. The Hearing Review, January 2013. Available at: https://www.hearingreview.com/hearing-products/accessories/headphones/for-whom-the-decibel-tolls-the-dba-vs-db-spl-war-january-2013-hearing-review

Hazardous noise is typically defined as a time-weighted average of ≥85 dbA for an 8-hour workday.

Figure 1. Anatomy of the ear showing the inner ear and cochlea

Hearing loss

In normal function, when noise occurs and vibrations reach the inner ear, this causes cochlear fluid to ripple and create a wave motion for the basilar membrane on which the cochlear hair cells sit. This causes the hair cells to move up and down. The stereocilia on top of these hair cells then bend, opening up their channels and permitting chemical intrusion that creates the neural signals conducted by the auditory nerve to the brain.7National Institute on Deafness and Other Communication Disorders. Noise-induced hearing loss. Available at: https://www.nidcd.nih.gov/health/noise-induced-hearing-loss. ,8American Dental Association. Safety tips to prevent hearing loss. Available at: https://success.ada.org/en/wellness/safety-tips-to-avoid-hearing-loss. ,9Murray ID. Hearing loss and tinnitus among dentists. The Hearing Journal, January 2020. Available at: doi: 10.1097/01.HJ.0000651540.52366.f5. (Figure 1)

Hearing loss may be sudden, due to an extremely loud noise (e.g., an exploding grenade). Exposure to lower-intensity noise can cause temporary hearing loss, or permanent hearing loss following continuous or repeated intermittent exposure.7National Institute on Deafness and Other Communication Disorders. Noise-induced hearing loss. Available at: https://www.nidcd.nih.gov/health/noise-induced-hearing-loss. NOHL is caused by sensorineural hearing loss which progresses slowly during long-term exposure to continuous or intermittent noise.8American Dental Association. Safety tips to prevent hearing loss. Available at: https://success.ada.org/en/wellness/safety-tips-to-avoid-hearing-loss. ,9Murray ID. Hearing loss and tinnitus among dentists. The Hearing Journal, January 2020. Available at: doi: 10.1097/01.HJ.0000651540.52366.f5.,10Messano GA, Petti S. General dental practitioners and hearing impairment. J Dent 2012;40:821-8. This results from damage to the cochlear hair cells.7National Institute on Deafness and Other Communication Disorders. Noise-induced hearing loss. Available at: https://www.nidcd.nih.gov/health/noise-induced-hearing-loss. ,9Murray ID. Hearing loss and tinnitus among dentists. The Hearing Journal, January 2020. Available at: doi: 10.1097/01.HJ.0000651540.52366.f5. (Figure 2) An individual may first experience difficulty with high-pitched sounds. Later, it can be difficult to hear at a given volume, sounds may be distorted and conversation can be difficult when there is background noise.8American Dental Association. Safety tips to prevent hearing loss. Available at: https://success.ada.org/en/wellness/safety-tips-to-avoid-hearing-loss.

NOHL is caused by sensorineural hearing loss which progresses slowly during long-term exposure to continuous or intermittent noise.

Figure 2. Cochlear hairs and stereocilia


Source: NIDCD/Yoshiyuki Kawashima

Tinnitus
Tinnitus may be the first sign of hearing loss and is caused by an imbalance in damage to the inner and outer cochlear hair cells.8American Dental Association. Safety tips to prevent hearing loss. Available at: https://success.ada.org/en/wellness/safety-tips-to-avoid-hearing-loss. Symptoms include a slight intermittent or continuous ringing or whistling sound in the ears, or it may be much more severe.8American Dental Association. Safety tips to prevent hearing loss. Available at: https://success.ada.org/en/wellness/safety-tips-to-avoid-hearing-loss. ,9,11Garner GG, Federman J, Johnson A. Noise induced hearing loss in the dental environment: An audiologist’s perspective. J Georgia Dent Assoc 2002:17-19. Severe tinnitus can impair quality of life due to the body responding to tinnitus as a threat, causing increased stress, hypertension and sleep disturbance.12Jastreboff PJ. Phantom auditory perception (tinnitus): Mechanisms of generation and perception. Neurosci Res 1990;8(4)221-54. Further, the stress response to noise exposure is believed to be linked to coronary heart disease.13Kerns E, Masterson EA, Themann CL, Calvert GM. Cardiovascular conditions, hearing difficulty, and occupational noise exposure within US industries and occupations. Am J Ind Med 2018;61(6):477-91. doi:10.1002/ajim.22833.

Figure 3. Relative findings on
audible frequency noise levels (db/dbA)14Myers J, John AB, Kimball S, Fruits T. Prevalence of tinnitus and noise‐induced hearing loss in dentists. Noise Health 2016;18(85):347‐54.,15Barek S, Adam O, Motsch JF. Large band spectral analysis and harmful risks of dental turbines. Clin Oral Investig 1999;3(1):49-54.,16Mueller HJ, Sabri ZI, Suchak AJ, McGill S, Standford JW. Noise level evaluation of dental handpieces. J Oral Rehabil 1986;13:279-92.,17Sorainen E, Rytkönen E. Noise level and ultrasound spectra during burring. Clin Oral Investig 2002;6(3):133-6.,18Theodoroff SM, Folmer RL. Hearing loss associated with long-term exposure to high-speed dental handpieces. Gen Dent 2015;63(3):71-6.,19Qsaibati ML, Ibrahim O. Noise levels of dental equipment used in dental college of Damascus University. Dent Res J (Isfahan) 2014;11(6):624-30.,20Sampaio Fernandes JC, Carvalho AP, Gallas M, Vaz P, Matos PA. Noise levels in dental schools. Eur J Dent Educ 2006;10(1):32-7. doi: 10.1111/j.1600-0579.2006.00393.x.,21Choosong T, Kaimook W, Tantisarasart R, Sooksamear P, Chayaphum S, Kongkamol C, et al. Noise exposure assessment in a dental school. Safe Health Work 2011;2(4):348-54. doi: 10.5491/SHAW.2011.2.4.348.,22Sorainen E, Rytkönen E. High-frequency noise in dentistry. AIHA J (Fairfax, Va) 2002;63(2):231-3.,23It’s a noisy planet. Protect their hearing. Free sound level meter app from CDC’s National Institute for Occupational Safety and Health. https://www.noisyplanet.nidcd.nih.gov/have-you-heard/cdc-niosh-app.

Sources of Noise in Dental Settings

The main sources of higher-intensity noise in the operatory are high-speed handpieces, ultrasonic scaling devices and high- and low-volume evacuation (HVE, SE). In one study, use of high-speed handpieces resulted in 70.4 to 83.6 dbA, and for a low-speed handpiece reached 70.4 dbA.14Myers J, John AB, Kimball S, Fruits T. Prevalence of tinnitus and noise‐induced hearing loss in dentists. Noise Health 2016;18(85):347‐54. In a second study, noise levels at audible and ultrasonic (inaudible) frequencies for one high-speed handpiece were 95 and 112 dB SPL, respectively.15Barek S, Adam O, Motsch JF. Large band spectral analysis and harmful risks of dental turbines. Clin Oral Investig 1999;3(1):49-54. For two other brands, ultrasonic noise levels ranged from 101 to 115 db SPL. In other studies, high-speed handpieces generated noise up to 87.4 dbA, 76-89 db SPL, 88 – 102 dbA and 89.7 dbA, respectively.16Mueller HJ, Sabri ZI, Suchak AJ, McGill S, Standford JW. Noise level evaluation of dental handpieces. J Oral Rehabil 1986;13:279-92.,17Sorainen E, Rytkönen E. Noise level and ultrasound spectra during burring. Clin Oral Investig 2002;6(3):133-6.,18Theodoroff SM, Folmer RL. Hearing loss associated with long-term exposure to high-speed dental handpieces. Gen Dent 2015;63(3):71-6.,19Qsaibati ML, Ibrahim O. Noise levels of dental equipment used in dental college of Damascus University. Dent Res J (Isfahan) 2014;11(6):624-30. In two recent studies in dental school clinics, reported noise levels were below or well below 85 dbA for handpieces and ultrasonic scalers.20Sampaio Fernandes JC, Carvalho AP, Gallas M, Vaz P, Matos PA. Noise levels in dental schools. Eur J Dent Educ 2006;10(1):32-7. doi: 10.1111/j.1600-0579.2006.00393.x.,21Choosong T, Kaimook W, Tantisarasart R, Sooksamear P, Chayaphum S, Kongkamol C, et al. Noise exposure assessment in a dental school. Safe Health Work 2011;2(4):348-54. doi: 10.5491/SHAW.2011.2.4.348. Noise levels of 79.3, 96.5 and 94.8 dBA, respectively, have been found for HVE, obstructed HVE, and use in combination with a high-speed handpiece.14Myers J, John AB, Kimball S, Fruits T. Prevalence of tinnitus and noise‐induced hearing loss in dentists. Noise Health 2016;18(85):347‐54. In a controlled laboratory study with no background noise, measurements of noise at audible and ultrasonic frequencies were taken during simulated procedures. Noise levels for handpieces, an ultrasonic scaler, HVE and SE were 76-82, 83, 77 and 75 dbA, respectively.22Sorainen E, Rytkönen E. High-frequency noise in dentistry. AIHA J (Fairfax, Va) 2002;63(2):231-3. In comparison, whispering and regular conversation generate 30 and 65-80 dB, respectively, while a motor cycle, a rock concert and fire truck sirens generate 80-100, 95 to 115 and 110 to 129 dB, respectively.23It’s a noisy planet. Protect their hearing. Free sound level meter app from CDC’s National Institute for Occupational Safety and Health. https://www.noisyplanet.nidcd.nih.gov/have-you-heard/cdc-niosh-app. The latter can result in some hearing loss in under a minute. (Figure 3)

Prevalence of NOHL in Dentistry

The prevalence of NOHL varies across studies. In one study comparing dentists (mean age 43.7 years) working for at least 10 years with physicians comparable by age and experience, hearing loss (including tinnitus) was 30% and 14.8%, respectively.10Messano GA, Petti S. General dental practitioners and hearing impairment. J Dent 2012;40:821-8. A statistically significant association was found for use of ultrasonic scalers and for high-speed handpieces in use for at least a year. In an audiometry study, the hearing of dentists using/not using high-speed handpieces for >20 years was compared, as well as for students with almost 3 years of clinical experience.18Theodoroff SM, Folmer RL. Hearing loss associated with long-term exposure to high-speed dental handpieces. Gen Dent 2015;63(3):71-6. At 4,000 to 8,000 Hz, statistically significant hearing loss had occurred in the right ear of clinicians using handpieces. Hearing loss in the left ear was statistically significant at 8,000 Hz in comparison to the other dental professionals and students, and at 3000 and 6000 Hz compared to students.

In contrast, no significant difference was found for hearing loss in dental clinicians compared to control groups in other studies.24Alabdulwahhab B, Alduraiby R, Ahmed M, Albatli LI, Alhumain MS, Softah NA, Saleh S. Hearing loss and its association with occupational noise exposure among Saudi dentists: a cross-sectional study. BDJ Open 2, 16006 (2016). doi.org/10.1038/bdjopen.2016.6,25Khaimook W, Suksamae P, Choosong T, Chayarpham S, Tantisarasart R. The prevalence of noise-induced occupational hearing loss in dentistry personnel. Workplace Health Saf 2014;62(9):357-60. However, in one of these studies, audiometry tests revealed a statistically significant difference only for individuals with at least 15 years of experience. In a pilot audiology study, a statistically significant difference in hearing loss was observed at 3000 Hz for dental hygienists with high but not low ultrasonic usage.26Wilson JD, Darby ML, Tolle SL, Sever JC Jr. Effects of occupational ultrasonic noise exposure on hearing of dental hygienists: a pilot study. J Dent Hyg 2002;76(4):262-9. In another study, impaired hearing was observed among dentists, dental assistants and prosthodontists tested using standard and high-frequency threshold audiometry and additional tests. In addition, the use of high-frequency threshold testing enabled detection of hearing loss without which only hearing loss attributable to lower frequencies would have been detected.27Lopes AC, de Melo AD, Santos CC. A study of the high-frequency hearing thresholds of dentistry professionals. Int Arch Otorhinolaryngol 2012;16(2):226-31.

In a survey with 144 respondants, among the 30 to 39 year age group no dentists reported hearing loss. The percentage of dentists ages 40 to 49 years and age 50 and over reporting hearing loss, respectively, was similar to and higher than in the general population.13Kerns E, Masterson EA, Themann CL, Calvert GM. Cardiovascular conditions, hearing difficulty, and occupational noise exposure within US industries and occupations. Am J Ind Med 2018;61(6):477-91. doi:10.1002/ajim.22833. Notably, the reported daily number of hours of use for handpieces, suction and ultrasonic scalers did correlate with self-reported loss of hearing and a higher percentage reported tinnitus than in the general population. Across four other surveys, hearing loss reported by dentists ranged from 3% (22 to 54-year-olds) to 21%, with 37% in one study reporting tinnitus, and among dental nurses surveyed in one study 5% reported hearing loss.28Chowanadisal S, Kukiauttakoon B, Yapong B, Kedjarune U, Leggat PA. Occupational health problems of dentists in southern Thailand. Int Dent J 2000;50:36-40.,29Ali-Ali K, Hashim R. Occupational health problems of dentists in the United Arab Emirates. Int Dent J 2012;62:52-6.,30Daud MK, Noh NF, Sidek DS, Rahman NA, Zakaria MN. Screening of dental staff nurses for noise induced hearing loss. B-ENT 2011;7:245-9.,31Gijbels F, Jacobs R, Princen K, Nackaerts O, Debruyne F. Potential occupational health problems for dentists in Flanders, Belgium. Clin Oral Investig 2006;10(1):8-16. doi:10.1007/s00784-005-0003-6. ,32Elmehdi HM. Noise levels in UAE dental clinics: Health impact on dental healthcare professionals. J Public Health Front 2013;2:189-92. In a survey of dental hygienists with at least 20 years of experience, 40% of respondents reported hearing loss.33Lazar A, Kauer R, Rowe D. Hearing difficulties among experienced dental hygienists: a survey. J Dent Hyg 2015;89(6):378‐83. Among respondents, 17% reported that hearing loss had occurred due to use of ultrasonic scalers and for 9 out of 10 of these individuals an audiologist had confirmed hearing loss. A statistically significant relationship was found for greater use of ultrasonic scalers. The prevalence of hearing loss was 2.5 times that of comparable females in the general population.

Preventing NOHL

Recommendations for prevention of NOHL include hearing tests, use of hearing protection devices (HPD) and considerations for equipment. A baseline test measuring hearing acuity is recommended together with regular annual re-evaluation that would enable early intervention.8American Dental Association. Safety tips to prevent hearing loss. Available at: https://success.ada.org/en/wellness/safety-tips-to-avoid-hearing-loss. High-frequency threshold testing and other non-standard tests, in conjunction with standard audiometry tests, have also been recommended to enhance early hearing loss detection.24Alabdulwahhab B, Alduraiby R, Ahmed M, Albatli LI, Alhumain MS, Softah NA, Saleh S. Hearing loss and its association with occupational noise exposure among Saudi dentists: a cross-sectional study. BDJ Open 2, 16006 (2016). doi.org/10.1038/bdjopen.2016.6 Sound levels can also be monitored. A free sound level meter app for iOS devices is available from NIOSH through iTunes.23It’s a noisy planet. Protect their hearing. Free sound level meter app from CDC’s National Institute for Occupational Safety and Health. https://www.noisyplanet.nidcd.nih.gov/have-you-heard/cdc-niosh-app. (Figure 4) This app is intended for use to measure occupational noise levels and the results can be saved and shared. An external, calibrated microphone is recommended to improve accuracy. Information on hearing protection is also available.

A baseline test measuring hearing acuity is recommended together with regular annual re-evaluation that would enable early intervention.

Figure 4. NIOSH sound level meter app

Hearing protection
Hearing protection devices (HPD) may be over-the-counter or custom passive HPD (earplugs), or active HPD with active sound control.34ADA Professional Product Review. Clinician’s perspectives on hearing protection devices. October 2016;11(20:1-5. https://www.ada.org/en/publications/ada-professional-product-review-ppr/archives/~/media/436B9E501D064A32A42D73770F84D715.ashx. HPD labels include noise reduction ratings (NRR) based on laboratory testing, ranging from an NRR of 0 to 30 db. For example, if the NRR is 20 this indicates a potential noise level reduction from 90 db to 70 db. In reality, poor placement, fit and incorrect use reduce HPD efficacy. It has been suggested that the NRR number of dB be ‘derated’ (reduced) for real-life situations.35Insight. How it works: Noise reduction ratings. October, 2019. https://www.soneticscorp.com/how-it-works-noise-reduction-ratings/.

Passive earplugs provide a physical barrier that reduces noise without differentiating by noise level, thereby impeding communication with patients.34ADA Professional Product Review. Clinician’s perspectives on hearing protection devices. October 2016;11(20:1-5. https://www.ada.org/en/publications/ada-professional-product-review-ppr/archives/~/media/436B9E501D064A32A42D73770F84D715.ashx. In contrast, active HPD are battery-operated electronic devices that attenuate hazardous noise, reducing the noise level without affecting non-hazardous noise.34ADA Professional Product Review. Clinician’s perspectives on hearing protection devices. October 2016;11(20:1-5. https://www.ada.org/en/publications/ada-professional-product-review-ppr/archives/~/media/436B9E501D064A32A42D73770F84D715.ashx. These devices are available as musicians HPD and as active HPD sold in the dental market under several brands (e.g., Music PRO, Denplugs, EarAID, and QuietOn). HPD can also be custom-fitted by an audiologist. Active HPD offer protection against hazardous noise without impacting communication with patients and the dental team, and rate well for comfort and appearance.8American Dental Association. Safety tips to prevent hearing loss. Available at: https://success.ada.org/en/wellness/safety-tips-to-avoid-hearing-loss. ,11Garner GG, Federman J, Johnson A. Noise induced hearing loss in the dental environment: An audiologist’s perspective. J Georgia Dent Assoc 2002:17-19.,34ADA Professional Product Review. Clinician’s perspectives on hearing protection devices. October 2016;11(20:1-5. https://www.ada.org/en/publications/ada-professional-product-review-ppr/archives/~/media/436B9E501D064A32A42D73770F84D715.ashx.

Active HPD offer protection against hazardous noise without impacting communication with patients and the dental team, and rate well for comfort and appearance.

Equipment and Environmental Considerations
Poor equipment maintenance is associated with increased noise during use.10Messano GA, Petti S. General dental practitioners and hearing impairment. J Dent 2012;40:821-8.,17Sorainen E, Rytkönen E. Noise level and ultrasound spectra during burring. Clin Oral Investig 2002;6(3):133-6.,18Theodoroff SM, Folmer RL. Hearing loss associated with long-term exposure to high-speed dental handpieces. Gen Dent 2015;63(3):71-6.,20Sampaio Fernandes JC, Carvalho AP, Gallas M, Vaz P, Matos PA. Noise levels in dental schools. Eur J Dent Educ 2006;10(1):32-7. doi: 10.1111/j.1600-0579.2006.00393.x. Proper maintenance of handpieces, ultrasonic scalers and compressors in accordance with the manufacturer’s IFU not only prolongs the life of these devices, it can also help prevent hearing loss.10Messano GA, Petti S. General dental practitioners and hearing impairment. J Dent 2012;40:821-8.,18Theodoroff SM, Folmer RL. Hearing loss associated with long-term exposure to high-speed dental handpieces. Gen Dent 2015;63(3):71-6. Noise level is also one of many considerations in selecting dental equipment. Office soundproofing, baffle drapes, resilient floors and noise-mitigating ceilings can also help to contain noise levels, as does positioning the compressor far away from operatories. (Table 1)

Table 1. Recommendations on preventing NOHL
Baseline hearing test and regular annual re-evaluation
Adjunctive high-frequency threshold testing, other tests24Alabdulwahhab B, Alduraiby R, Ahmed M, Albatli LI, Alhumain MS, Softah NA, Saleh S. Hearing loss and its association with occupational noise exposure among Saudi dentists: a cross-sectional study. BDJ Open 2, 16006 (2016). doi.org/10.1038/bdjopen.2016.6
Use of hearing protection devices (HPD)
Proper equipment maintenance
Office design and layout considerations

Conclusions

Several studies have demonstrated noise levels in excess of the recommended threshold level. Results from studies and surveys vary, while length of years worked, duration of workdays and usage of noise-generating equipment is associated with NOHL. In addition, impaired communication resulting from use of HPD has been a barrier to use and low levels of adoption have been reported.18Theodoroff SM, Folmer RL. Hearing loss associated with long-term exposure to high-speed dental handpieces. Gen Dent 2015;63(3):71-6.,33Lazar A, Kauer R, Rowe D. Hearing difficulties among experienced dental hygienists: a survey. J Dent Hyg 2015;89(6):378‐83. Longitudinal studies assessing hearing acuity and the prevalence of NOHL among dental professionals, as well as studies on educational interventions that would increase HPD use have been recommended.14Myers J, John AB, Kimball S, Fruits T. Prevalence of tinnitus and noise‐induced hearing loss in dentists. Noise Health 2016;18(85):347‐54.,18Theodoroff SM, Folmer RL. Hearing loss associated with long-term exposure to high-speed dental handpieces. Gen Dent 2015;63(3):71-6.,36Hyson JM Jr. The air turbine and hearing loss: are dentists at risk? J Am Dent Assoc 2002;133(12):1639-42. It is recommended that dental professionals have regular hearing tests, wear HPD and consider equipment and environmental factors. It behooves the dental team to routinely use HPD, and active sound control HPD offers a solution that preserves communication with patients and the team. Ultimately, NOHL is preventable.

References

  • 1.American Dental Association. Antibiotic prophylaxis prior to dental procedures. Available at: https://www.ada.org/en/member-center/oral-health-topics/antibiotic-prophylaxis.
  • 2.Newton T, Asimakopoulou K, Daly B, Scambler S, Scott S. The management of dental anxiety: time for a sense of proportion? Br Dent J 2012;213(6):271-4.
  • 3.Jena A, Shashirekha G. Effect of preoperative medications on the efficacy of inferior alveolar nerve block in patients with irreversible pulpitis: A placebo-controlled clinical study. J Conserv Dent 2013;16(2):171-4.
  • 4.Pulikkotil SJ, Nagendrababu V, Veettil SK, Jinatongthai P, Setzer FC. Effect of oral premedication on the anaesthetic efficacy of inferior alveolar nerve block in patients with irreversible pulpitis: A systematic review and network meta-analysis of randomized controlled trials. Int Endod J 2018;51(9):989-1004.
  • 5.Argueta-Figueroa L, Arzate-Sosa G, Mendieta-Zeron H. Anesthetic efficacy of articaine for inferior alveolar nerve blocks in patients with symptomatic versus asymptomatic irreversible pulpitis. Gen Dent 2012;60:e39-43.
  • 6.Aggarwal V, Singla M, Subbiya A, Vivekanandhan P, Sharma V, Sharma R, Prakash V, Geethapriya N. Effect of preoperative pain on inferior alveolar nerve block. Anesthesia Progress 2015;62:135–9.
  • 7.Fullmer S, Drum M, Reader A, Nusstein J, Beck M. Effect of preoperative acetaminophen/hydrocodone on the efficacy of the inferior alveolar nerve block in patients with symptomatic irreversible pulpitis: a prospective, randomized, double-blind, placebo-controlled study. J Endod 2014;40(1):1-5.
  • 8.Pak JG, White SN. Pain prevalence and severity before, during, and after root canal treatment: A systematic review. J Endod 2011;37:429-38.
  • 9.Ghoddusi J, Zarrabi MH, Daneshvar F, Naghavi N. Efficacy of IANB (RR) and Gow-Gates techniques in mandibular molars with symptomatic irreversible pulpitis: A prospective randomized double blind clinical study. Iran Endod J 2018;13(2):143-8.
  • 10.Rood JP. Some anatomical and physiological causes of failure to achieve mandibular analgesia. Br J Oral Surg 1977;15(1):75-82.
  • 11.Sivaramakrishnan G, Sridharan K. Oral ketorolac with inferior alveolar nerve block for irreversible pulpitis: A systematic review and meta-analysis. The Open Dent J 2018;12:340-6.
  • 12.Dou L, Vanschaayk MM, Zhang Y, Fu X, Ji P, Yang D. The prevalence of dental anxiety and its association with pain and other variables among adult patients with irreversible pulpitis. BMC Oral Health 2018;18(1):101.
  • 13.Gow-Gates GA. Mandibular conduction anesthesia: a new technique using extraoral landmarks. Oral Surg Oral Med Oral Pathol 1973;36(3):321-8.
  • 14.Matthews R, Drum M, Reader A, Nusstein J, Beck M. Articaine for supplemental buccal mandibular infiltration anesthesia in patients with irreversible pulpitis when the inferior alveolar nerve block fails. J Endod 2009;35:343–6.
  • 15.Dubin AE, Patapoutian A. Nociceptors: the sensors of the pain pathway. J Clin Invest 2010;120(11):3760-72.
  • 16.Graham GG, Davies MJ, Day RO, Mohamudally A, Scott KF. The modern pharmacology of paracetamol: therapeutic actions, mechanism of action, metabolism, toxicity and recent pharmacological findings. Inflammopharmacol 2013;21(3):201-32.
  • 17.Beakley BD, Kaye AM, Kaye AD. Tramadol, pharmacology, side effects, and serotonin syndrome: A review. Pain Physician 2015;18:395-400.
  • 18.Li C, Yang X, Ma X, Li L, Shi Z. Preoperative oral nonsteroidal anti-inflammatory drugs for the success of the inferior alveolar nerve block in irreversible pulpitis treatment: a systematic review and meta-analysis based on randomized controlled trials. Quintessence Int 2012;43(3):209-19.
  • 19.Shirvani A, Shamszadeh S, Eghbal MJ, Marvasti LA, Asgary S. Effect of preoperative oral analgesics on pulpal anesthesia in patients with irreversible pulpitis: A systematic review and meta-analysis. Clin Oral Investig 2017; 21(1):43-52.
  • 20.Nagendrababu V, Pulikkotil SJ, Veettil SK, Teerawattanapong N, Setzer FC. Effect of nonsteroidal anti-inflammatory drug as an oral premedication on the anesthetic success of inferior alveolar nerve block in treatment of irreversible pulpitis: A systematic review with meta-analysis and trial sequential analysis. J Endod 2018;44(6):914-22.e2.
  • 21.Bidar M, Mortazavi S, Forghani M, Akhlaghi S. Comparison of effect of oral premedication with ibuprofen or dexamethasone on anesthetic efficacy of inferior alveolar nerve block in patients with irreversible pulpitis: a prospective, randomized, controlled double-blind study. Bull Tokyo Dent Coll 2017;58(4):231-6.
  • 22.Shahi S, Mokhtari H, Rahimi S, Yavari HR, Narimani S, Abdolrahimi M, Nezafati S. Effect of premedication with ibuprofen and dexamethasone on success rate of inferior alveolar nerve block for teeth with asymptomatic irreversible pulpitis: a randomized clinical trial. J Endod 2013;39(2):160-2.
  • 23.Aggarwal V, Singla M, Kabi D. Comparative evaluation of effect of preoperative oral medication of ibuprofen and ketorolac on anesthetic efficacy of inferior alveolar nerve block with lidocaine in patients with irreversible pulpitis: a prospective, double-blind, randomized clinical trial. J Endod 2010;36(3):375-8.
  • 24.Parirokh M, Ashouri R, Rekabi AR, Nakhaee N, Pardakhti A, Askarifard S, Abbott PV. The effect of premedication with ibuprofen and indomethacin on the success of inferior alveolar nerve block for teeth with irreversible pulpitis. J Endod 2010;36:1450-4.
  • 25.Lamba S, Swamy UKP, Kaushik M, Reddy PY, Kumar P. Effect of premedication with ibuprofen and meloxicam on the efficacy of inferior alveolar nerve block in irreversible pulpitis. J Med Sci Clin Res 2018;6(5):290-5.
  • 26.Oleson M, Drum M, Reader A, Nusstein J, Beck M. Effect of preoperative ibuprofen on the success of the inferior alveolar nerve block in patients with irreversible pulpitis. J Endod 2010;36(3):379-82.
  • 27.Simpson M, Drum M, Nusstein J, Reader A, Beck M. Effect of preoperative ibuprofen/acetaminophen on the success of the inferior alveolar nerve block in patients with symptomatic irreversible pulpitis. J Endod 2011;37(5):593–7.
  • 28.Stanley W, Drum M, Nusstein J, Reader A, Beck M. Effect of nitrous oxide on the efficacy of the inferior alveolar nerve block in patients with symptomatic irreversible pulpitis. J Endod 2012;38(5):565-9.
  • 29.Stentz D, Drum M, Reader A, Nusstein J, Fowler S, Beck M. Effect of a combination of intranasal ketorolac and nitrous oxide on the success of the inferior alveolar nerve block in patients with symptomatic irreversible pulpitis: A prospective, randomized, double-blind study. J Endod 2018; 44(1):9-13.
  • 30.Lindemann M, Reader A, Nusstein J, Drum M, Beck M. Effect of sublingual triazolam on the success of inferior alveolar nerve block in patients with irreversible pulpitis. J Endod 2008;34(10):1167-70.
  • 31.Delphin-Rittmon ME, Andres-Hyman R, Flanagan EH, Davidson L. Seven essential strategies for promoting and sustaining systemic cultural competence. Psychiatr Q 2013;84(1):53-64. doi: 10.1007/s11126-012-9226-2.
  • 32.Tiwari T, Jamieson L, Broughton J, Lawrence HP, Batliner TS, Arantes R, Albino J. Reducing indigenous oral health inequalities: A review from 5 nations. J Dent Res 2018;97(8):869-77. doi: 10.1177/0022034518763605.
  • 33.Trombelli L, Farina R, Ferrari S, Pasetti P, Calura G. Comparison between two methods for periodontal risk assessment. Minerva Stomatol 2009;58:277-87.
  • 34.Persson GR, Mancl LA, Martin JA, Page RC. Assessing periodontal disease risk. J Am Dent Assoc 2003;134(5):575-82.
  • 35.Martin JA, Grill AC, Matthews AG, Vena D, Thompson VP, Craig RG, Curro FA. Periodontal diagnosis affected by variation in terminology. Periodontol 2013;84:606-13.
  • 36.Lang NP, Suvan JE, Tonetti MS. Risk factor assessment tools for the prevention of periodontitis progression a systematic review. J Clin Periodontol 2015;42(S16):S59-70.
  • 37.Mertz E, Wides C, White J. Clinician attitudes, skills, motivations and experience following the implementation of clinical decision support tools in a large dental practice. J Evid Based Dent Pract 2017;17(1):1-12.
  • 38.Martin J, Mills S, Foley ME. Innovative models of dental care delivery and coverage. Patient-centric dental benefits based on digital oral health risk assessment. Dent Clin N Am 2018;62:319-25.
  • 39.Mills SE. Creating a risk-based model for dental benefit design. J Dent Hyg 2015;89(Suppl 1):24-6.
  • 40.Shimazaki Y, Akifusa S, Takeshita T, Shibata Y, Doi Y, Hata J, Ninomiya T, Hirakawa Y, Kiyohara Y, Yamashita Y. Effectiveness of the salivary occult blood test as a screening method for periodontal status J Periodontol. 2011;82(4):581-7.
  • 41.Reed SG, Manz M, Snipe SM, Ohshimna M, Wagner CL. Feasibility study of a salivary occult blood test to correlate with periodontal measures as indicators of periodontal inflammation in a population of pregnant women. J Oral Sci 2015;57(1): 55-8.
  • 42.Kim JJ, Kim CJ, Camargo PM. Salivary biomarkers in the diagnosis of periodontal diseases. J Calif Dent Assoc. 2013;41(2):119-24.
  • 43.Korte DL, Kinney J. Personalized medicine: an update of salivary biomarkers for periodontal diseases. Periodontol 2000 2016;70:26-37.
  • 44.Cekici A, Kantarci A, Hasturk H, Van Dyke TE. Inflammatory and immune pathways in the pathogenesis of periodontal disease. Periodontol 2000 2014;64(1):57-80.
  • 45.Liu YC, Lerner UH, Teng YT. Cytokine responses against periodontal infection: protective and destructive roles. Periodontol 2000 2010;52:163-206.
  • 46.Steinsvoll S, Halstensen TS, Schenck K. Extensive expression of TGF-beta1 in chronically-inflamed periodontal tissue. J Clin Periodontol 1999;26:366-73.
  • 47.Garlet GP. Destructive and protective roles of cytokines in periodontitis: a re-appraisal from host defense and tissue destruction viewpoints. J Dent Res 2010;89:1349-63.
  • 48.Reis C, Costa AV, Guimarães JT, Tuna D, Braga AC, Pacheco JJ, Arosa FA, Salazar F, Cardoso EM. Clinical improvement following therapy for periodontitis: Association with a decrease in IL-1 and IL-6 Exp Ther Med. 2014;8(1):323-7.
  • 49.Giannobile WV. Salivary diagnostics for periodontal diseases. J Am Dent Assoc 2012;143(Suppl 10):6S–11S.
Login to access